date BS EN is withdrawn and BS EN and BS EN In addition IEC and IEC have been amended, clarified and. For each type of electrical AssEMBLY only two parts of the standard are necessary to determine all requirements: the basic standard IEC “ General rules. What changes does BS EN bring? • New testing procedure including design and routine verification. • Alternative testing routes. • Clear requirements for.

Author: Tashura Akisar
Country: Great Britain
Language: English (Spanish)
Genre: Technology
Published (Last): 9 January 2009
Pages: 346
PDF File Size: 5.49 Mb
ePub File Size: 12.39 Mb
ISBN: 191-6-96416-961-9
Downloads: 49664
Price: Free* [*Free Regsitration Required]
Uploader: Masar

Verification shall comprise the following categories: The high-voltage transformer used for the test shall be so designed that, when the output terminals are short-circuited after the output voltage has been adjusted to the appropriate test voltage, the output current shall be at least mA.

The method of verifying clearances by measurement is given in Annex F. The emission and immunity tests shall be carried out in accordance with the relevant EMC standard see Tables J. It is incorporated by Royal Charter.

The value of the short-circuit current shall be the same as that for the main busbars. The values are given in Tables J. Where alternative protective devices can be incorporated in the outgoing unit, the protective device which eh 2through the maximum values of peak current and It shall be used.

If these details are to be usedfor any other purpose than implementation then the prior written permissionof BSI must be obtained. The continuity of the protective circuit of a withdrawable part shall remain effective from the connected position to the isolated position inclusively. NOTE 1 The rated current of a circuit may be lower than the rated currents of the devices according to the respective device standard installed in this circuit. If the ccSCPD contains an adjustable short-circuit release, then this shall be set to the maximum allowed value see 9.

For PEN conductors, the following additional requirements apply: In case of doubt associated with paints and varnishes, reference shall be made to ISO to 16439-1 that the samples conform to the specimen Ri1; — the mechanical integrity is not impaired; — seals are not damaged, — doors, hinges, locks, and fastenings work without abnormal effort.

  ESSO - NUTO H32 PDF

This creepage distance path includes a Rule: Other materials may have a different maximum temperature rise. Arrangements with long faces horizontal may be used if specified by the manufacturer.

BS EN 低压开关设备和控制设备.总则 – MBA智库文档

Auxiliary circuits not connected to main circuits shall be connected to earth. The test specimens shall be new and in a clean condition and shall 614439-1 subjected to severity test A sn B, as detailed in To make the test representative the external surfaces at which additional sections may be connected shall be thermally insulated with a covering to prevent any undue cooling.

We would be grateful if anyone finding an inaccuracy or ambiguity whileEmail: The clearances of such circuits — a. A list of organizations represented on this subcommittee can be obtained on request to its secretary.

Introduction to 61439-1

If, however, momentary contact separation occurs in the protective device, if any, during the test, the test shall be repeated at the maximum operational voltage. If necessary, a resistor limiting the current to that value shall be used. For switching devices and components inside an enclosure, the pollution degree of the environmental conditions in the enclosure is applicable.

In addition to the current-carrying capacity of the conductors, the selection is governed by: The critical functional unit shall at least be tested inside the smallest compartment if any which is intended for this functional unit; and with the worst variant of internal separation if any with respect to size of ventilation openings; and the enclosure with the highest installed power loss per volume; and the worst variant of ventilation of the enclosure with respect to kind of ventilation natural or forced convection and size of ventilation openings.

Paints, varnishes and lacquers alone are not considered to satisfy the requirements for basic insulation.

NFPA 70, Article Arrangements shall ensure electrical separation not less than that between the input and output of an isolating transformer.

For the electrical conditions associated with the different positions of withdrawable parts, see Table If the direction of operation is not in accordance with IECthen the direction of operation shall be clearly identified.

Sb for safety — Protection against voltage disturbances and electromagnetic disturbances IEC To minimize danger when replacing fuse-links, interphase barriers shall be applied, unless the design and location of the fuses makes this unnecessary.

  ENFAMIL $5 COUPON PDF

The minimum length to a star point shall be 2 m.

NOTE 2 Due to the complex factors determining the rated currents, no standard values can be given. An ASSEMBLY used or tested under installation conditions may have connections, the type, nature and disposition of which will not be the same as those adopted for the test, and a different temperature rise of bz may result and may be required or accepted.

NOTE 3 The value of the supply voltage may exceed the rated voltage due to permissible system tolerances.

NOTE 3 The term “flashover” is used when a disruptive discharge occurs over the surface of a dielectric in a gaseous or liquid medium. The degree of protection shall be at least IP XXB; — protection against the passage of solid foreign bodies.

Gap between head of screw and wall of Rule: Co-ordination of switching devices and components, for example co-ordination of motor starters with short-circuit protective devices, shall comply with the relevant IEC standards. All other circuits shall be verified. The total effective power loss should be calculated for 12 outgoing circuits loaded with 8 A each.

The requirements are that any insulation material used to support current carrying parts must be able to withstand a glow-wire test at o C. It shall be connected to the main or the distribution busbar as in normal use. Where a conductive obstacle is separated from hazardous live parts by basic protection only, it is an exposed conductive part, and measures for fault protection shall also be applied.

Sheathed cables for fixed wiring IEC If, after the removal of a removable part, the original degree of protection is not maintained, an agreement shall be reached between the ASSEMBLY manufacturer and the user as to what measures shall be taken to ensure adequate protection. Type of protection against electric shock — Fault 8. Blackburn Starling has implemented these changes and is able to offer a product which complies with these new standards. The test shall be carried out on an enclosure or representative sample showing the same constructional detail as the enclosure itself.